Tel: +86-13924628001
Home Product > Remote Telemetry Antenna
  • 24单元阵列-竖立-1-removebg_看图王

Digital beam self-tracking array antenna

Description:

Consult

Product Description:

1. The antenna array is composed of a two-layer structure, the upper layer is an antenna array composed of 12 units, and the lower structure includes a calibration network and 12 dual-channel low noise amplifiers;

2. 12 units are arranged according to 2×6 to form a rectangular plane array, and each unit is composed of two orthogonal double-polarized symmetric oscillators to form left-right double-polarization;

3, each dual low noise amplifier contains two identical amplification branches, respectively, the antenna received left circular polarization and right circular polarization signal for low noise amplification and filtering;

4. The calibration network distributes the input reference signal to 12 dual low noise amplifiers according to the principle of constant amplitude in phase; The dual-channel low noise amplifier selects the antenna signal or the reference signal through the RF switch;

5, amplifier circuit gain is high, low noise factor, with high dynamic reception function;

6, antenna and circuit do three protection treatment;

7, unique waterproof and dustproof design, to meet the waterproof IP67, to ensure that the core units and components are completely sealed, to meet the complex outdoor environment, can work normally outdoors for a long time.


Electrical Specifications

Frequency Range(MHz):2200~2400

Gain(dBi):≥6(Zenith direction)

Polarization:Double circular polarization

3dB Beamwidth(°):Azimuth ≥120° Pitch ≥60°


Dual low noise amplifier circuit:

Frequency Range(MHz):2200~2400

LNA Gain(dB):35±2

Mode control signal:

Through-core capacitance, TTL level, inverter isolation

The high level corresponds to the antenna signal, and the low level corresponds to the reference signal

Burn resistance (W) : 2W

Calibration mode isolation: the antenna signal is cut off, and the insertion loss is not less than 40dB

Calibration port consistency: The amplitude difference between the calibration port and the two inputs does not exceed ±0.2dB. The phase difference between the calibration port and the two inputs does not exceed ±1 degree

 

Mechanical Specifications

Connector                                           

X1:Y50X10-1824Z10KX2:J599/20WB01A1NF1

X3:SMA-K    

X4:SMA-K

X5:SMA-K    

X6:TNC-K

Dimensions(mm):858×170×84

Weight(kg):≤10  



Tel

+86 13924628001

Follow us

客服

Consult